USA EPA rule on HFC refrigerants — important information
Any specified components intended for use with an HFC refrigerant or refrigerant blend containing an HFC is for servicing existing equipment only, unless the end use is not covered by the Environmental Protection Agency (EPA) Transition Rule. Before using the specified component with a regulated substance, please check the Environmental Protection Agency (EPA) rules at the EPA website.
More information about the suitable refrigerants for each product, please access our Product-Selector Software.
To understand what refrigerant the specified component is intended for use with, please see the tables below:
Compressors Families
Compressor Family
Efficiency level
Standard generation
First generation
Second generation
Third generation
Fourth generation
Fifth generation
Sixth generation
Mechanical kit
Standard mechanical kit
Non standard
Compressor capacity in BTU/H - 60Hz - Ashrae
Check point divided by 10
Application
Standard efficiency (LBP)
Intermediate efficiency (LBP)
Improved efficiency first generation (LBP)
Improved efficiency second generation (LBP)
Standard efficiency (L/M/HBP)
Standard efficiency (HBP)
Standard efficiency (M/HBP)
Refrigerant Code
R401A, R401B and R409A
R600a
R134a; R513A and R450A
R290
Electrical equipment
LST:
P PTC + Run Cap (optional)
R Relay
C PTC + Run Cap (mandatory)
S PTC + Run Cap + Start Cap
V PTC + Run Cap + Start Cap (optional)
HST:
X Relay + Start Cap (mandatory)
Compressor family
Standard efficiency
Standard generation
Improved efficiency first generation
Improved efficiency second generation (for commercial refrigeration)
Mechanical kit
Standard mechanical kit
Non standard
Approximate capacity in Btu/h - 60Hz
ASHRAE - checkpoint divided by 10
Refrigerant Code
R401A, R401B and R409A
R134a; R513A and R450A
R290
R1234yf
Application
L / MBP
L / M / HBP
Starting characteristic
LST (Low Starting Torque)
HST (High Starting Torque)
Compressor family
Commercial EM / NE / NT / NJ
Efficiency level
First generation
Second generation
Third generation
Fourth generation
Fifth generation
Sixth generation
Application code
LBP / HST
L- MBP / LST
L-MBP / HST
M-HBP / LST
M-HBP / HST
M-HBP / HST
The first digit is the number of zeros that must be added to the last two digits to obtain the cooling capacity (approx.) in kcal/h at 50 Hz.
E.g.: 144= 440 kcal/h at 50 Hz.
Refrigerant Code
R404A; R448A; R449A; R452A and R407C
R455A; R454C
R290; R454C
R134a; R513A and R450A
R600a
IPR valve
Available for some models
Compressor Family
VEG
Product generation
First generation
Second generation
Third generation
Fourth generation
Fifth generation
Sixth generation
Displacement
in cm³
Refrigerant Code
R134a
R600a
R290
R1234yf
Evaporation range
Extended evaporation range until 23 F (L/MBP)
Standard evaporation range
Compressors Families
VEM / FMF / VNE
Efficiency level
First generation
Second generation
Third generation
Fourth generation
Application and torque
LBP / LST
LBP / HST
L-MBP / LST
L-MBP / HST
M-HBP / LST
M-HBP / HST
Displacement
in cm³
Refrigerant Code
R290
R134a, R450A, R513A
R123yf
R404A, R448A, R449A, R452A and R407A
Condensing units
First Generation
Product Platform
Condensing unit
Compressor Family
Efficiency level
Standard generation
First generation
Second generation
Third generation
Fourth generation
Fifth generation
Sixth generation
Mechanical kit
Standard mechanical kit
Non standard
Compressor capacity in BTU/H - 60Hz - Ashrae
Check point divided by 10
Application
Standard efficiency (LBP)
Intermediate efficiency (LBP)
Improved efficiency first generation (LBP)
Improved efficiency second generation (LBP)
Standard efficiency (L/M/HBP)
Standard efficiency (HBP)
Standard efficiency (M/HBP)
Refrigerant Code
R401A, R401B and R409A
R600a
R134a; R513A and R450A
R290
Electrical equipment
LST:
P PTC + Run Cap (optional)
R Relay
C PTC + Run Cap (mandatory)
S PTC + Run Cap + Start Cap
V PTC + Run Cap + Start Cap (optional)
HST:
X Relay + Start Cap (mandatory)
Product Platform
Condensing Unit
Compressor Family
Standard efficiency
Improved efficiency first generation
Improved efficiency second generation (for commercial refrigeration)
Mechanical kit
Standard mechanical kit
Non standard
Approximate capacity in Btu/h - 60Hz
ASHRAE - checkpoint divided by 10
Refrigerant Code
R401A, R401B and R409A
R134a; R513A and R450A
R290
R1234yf
Application
L/MBP
L/M/HBP
Starting Characteristic
LST (Low Starting Torque)
HST (High Starting Torque)
Product platform
Condensing unit
Compressors Families
Commercial EM / NE/ NT / NJ
Efficiency level
First generation
Second generation
Third generation
Fourth generation
Fifth generation
Sixth generation
Application code
LBP / HST
L-MBP / LST
L-MBP / HST
M-HBP / LST
M-HBP / HST
M-HBP / HST
The first digit is the number of zeros that must be added to the last two digits to obtain the cooling capacity (approx.) in kcal/h at 50 Hz.
E.g.: 144= 440 kcal/h at 50 Hz.
Refrigerant Code
R404A; R448A; R449A; R452A and R407C
R455A; R454C
R290; R454C
R134a; R513A and R450A
R600a
IPR valve
Available for some models
Product Platform
Condensing unit
Compressor Family
VEG
Product generation
First generation
Second generation
Third generation
Fourth generation
Fifth generation
Sixth generation
Displacement
in cm³
Refrigerant Code
R134a, R450A, R513A
R600a
R290
R1234yf
Evaporation range
Extended evaporation range until 23 F (L/MBP)
Standard evaporation range
Second Generation
Use
Indoor
Compressors Families
EM / F / NE / NT / NJ
HP example
0150 : 150HP
0025 : 25HP
Application
LBP
MBP
L / MBP
Refrigerant Code
R404A, R404A, R448A, R449A, R452A and R407A
R455A;R454C
R134a, R513A and R450A
R290
Input voltage
220W/1/50 - 60Hz
280-230V/1/60Hz
115 - 127V/1/60HzG -115V/1/60Hz
Bare
Condenser
Finned condenser
Water cooled
Mechanical Component
No components
Version
Version
Version
Customized
Electrical component
No components
Version
Version
A
Version
Evaporative Drain Pan
Product Platform
Condensing Unit
Compressors Families
ES platform
EM platform
F platform
EH platform
NE platform
NT platform
NJ platform
Platform rating
Based on ARILBP or
ARIMBP performance
Application
LBP
MBP
L/MBP
M/HBP
Refrigerant Code
R404A, R404A, R448A, R449A, R452A and R407A
R134a/R450A/R513A
R290
R455A; R454C
Input Voltage
220V/1ph/50-60Hz
208-230V/1ph/60Hz
115-127V/1ph/60Hz
115V/1ph/60Hz
220-240V/1ph/50Hz
Condenser
Finned air cooled
Water cooled
Helical
CDU type - XX
Bare - 44
Plus - 24
Custom #1 - 03
Baseplate
Small EDP
Medium EDP
Product Platform
Condensing Unit
Compressors Families
FMS platform
FMX platform
VES platform
VEM platform
FMF platform
VNE platform
VNT platform
0020
Platform rating
Based on ARILBP or
ARIMBP performance
Application
LBP
MBP
L/MBP
M/HBP
Refrigerant Code
R404A, R448A, R449A, R452A and R407A
R134a/R450A/R513A
R290
R455A; R454C
Input Voltage
220V/1ph/50-60Hz
208-230V/1ph/60Hz
115-127V/1ph/60Hz
115V/1ph/60Hz
220-240V/1ph/50Hz
Condenser
Finned air cooled
Water cooled
Helical
CDU type - XX
Bare - 44
Plus - 24
Custom #1 - 03
Baseplate
Small EDP
Medium EDP
Sealed Units
Product Platform
Sealed Unit
Compressors Families
FMF / F
Efficiency level
Standard efficiency
Top efficiency
Application and torque
LBP / LST
LBP / HST
L-MBP / LST
L-MBP / HST
M-HBP / LST
M-HBP / HST
Displacement
in cm³.
Refrigerant Code
R290
R134a, R450A, R513A
R123yf
R404A, R404A, R448A, R449A, R452A and
R407A
R455A; R454C